Running Watts product guide
Generac 7326 24kW Home Standby Generator with 200A Transfer Switch (G0073260)
Whole-home standby power with a 200 A service-rated switch on a pro install
Generac's 7326 bundles a 24 kW air-cooled standby generator, 22.5 kW on natural gas, with a 200-amp service-rated transfer switch and cellular Mobile Link. The battery is not included, the main breaker figure differs between Generac documents, and warranty labor covers years one and two.
Listing checked . Confirm the model, included parts and availability before ordering.
Published specifications
- Spec sheet: 24 kW LP / 22.5 kW NG; 100/94 A at 240V
- Spec sheet: 200 A service-rated switch with surge protection; US only
- Spec sheet: 997cc G-Force 1000; about 2.2 qt oil; 461 lb
- Spec sheet: 67 dB(A) at 23 ft normal load; 55 dB(A) Quiet-Test
- Manual: battery not included (BTX30L 400 CCA minimum)
- Warranty: 5 yr/2,000 h; labor yrs 1-2, parts yr 3, major parts yrs 4-5
Fit and limits
Strengths
- 200 A service-rated switch with surge protection in the bundle
- Two-year or 200-hour service interval after break-in
- Generac publishes spec sheet, manuals and warranty for this variant
Caveats
- 22.5 kW on natural gas, not the 24 kW in the title
- Battery not included; breaker rating differs between documents
- Labor covered only in warranty years one and two
What this is: a 24 kW standby generator bundled with a 200-amp switch
Generac model 7326, variant G0073260, is its 24 kW air-cooled home standby generator bundled with a 200-amp transfer switch and built-in cellular connectivity. The spec sheet lists G007326-0 as the 24 kW bundle with UPC 696471104745, the same UPC as this listing. It runs on natural gas or propane and starts automatically when utility power fails.
It is a permanent installation. The owner's manual says only qualified service personnel may install, operate and maintain it, the Field Pro app is required for installation, and the unit must be registered and configured before it will run in AUTO. The warranty applies only to permanently wired and mounted units.
24 kW on propane, 22.5 kW on natural gas
Generac's spec sheet and product page rate the 24 kW model at 24 kW maximum on propane and 22.5 kW on natural gas, with 100 or 94 amps at 240V. Amazon's title and table give 24,000 watts without separating the fuels. The owner's manual notes a typical natural-gas derate.
Full-load fuel use is 291 cubic feet per hour of natural gas or 3.71 gallons per hour of propane, and the fuel pipe must be sized for full load at 3.5 to 7 inches of water column for natural gas or 10 to 12 inches for propane. The owner's manual recommends at least a 250-gallon propane tank when converting from natural gas.
The 200-amp service-rated transfer switch
The spec sheet lists G007326-0 with a 200-amp service-rated transfer switch, part A0005902810, in a NEMA 3R enclosure. It includes a fuse control module and integrated surge protection, is rated for 80 percent continuous load, and weighs 33 pounds.
The spec sheet says 200-amp service-entrance switches are certified for US use only. Generac lists load managers and an HVAC manager as optional accessories. Ask your installer whether your air conditioners or other large loads need managing on a 24 kW system.
Engine, weight, noise and a breaker figure to confirm
The spec sheet lists a two-cylinder 997cc G-Force 1000 engine with hydraulic lifters and about 2.2 quarts of oil including the filter. Weight is 461 pounds, matching Amazon and the product page, and dimensions are 46.4 by 26.3 by 30.7 inches. Noise is 67 dB(A) at 23 feet under normal load and 55 dB(A) in Quiet-Test low-speed exercise, from the front.
The product page lists a 100-amp main line breaker for this model. The spec sheet and owner's manual tables list 100, 110 and 125-amp breakers across the 22 to 28 kW models, and the text we extracted does not tie one figure clearly to the 24 kW. Have the installer confirm the breaker from the unit's data decal before sizing wiring.
Battery, placement and maintenance
The spec sheet and owner's manual say the battery is not included and must be a 12V AGM Powersport Group BTX30L with at least 400 CCA; the product page names a BTX20L 310CCA instead, so follow the manual. The manual says external chargers should not be used. The spec sheet allows installation as close as 18 inches to a structure, away from doors, windows and air intakes.
The owner's manual keeps mechanical air intakes at least 10 feet away and shrubs 3 feet from the louvers. Service starts with an oil and filter change after 25 hours, then oil, filter and battery check every two years or 200 hours, adding air filter and spark plugs every four years or 400 hours. Below 40°F or in continuous operation above 85°F, oil and filter move to every year or 100 hours.
Warranty: five years, narrowing after year two
Amazon and the product page describe a 5-year limited warranty, and the spec sheet says it covers the generator and transfer switch. Generac's written statement covers five years or 2,000 hours from successful start-up or online activation: parts, labor and limited travel in years one and two, parts only in year three, and major components only in years four and five.
Major components means the engine short block and alternator rotor and stator. The unit must be registered with proof of purchase, and warranty work must be done by an Independent Authorized Service Dealer. Proof of required maintenance must be available, travel is capped at 100 miles and three hours, and maintenance, installation and start-up costs are excluded.
Check the current listing
Confirm the model, included parts and availability before ordering.
Primary sources
- Generac product page, 24kW standby generator with transfer switch, variant G0073260
- Generac spec sheet, 22-28 kW air-cooled standby generators (A0005151077)
- Generac owner's manual, 60 Hz air-cooled generators 10-28 kW (A0004332577)
- Generac 5-year limited warranty for residential standby generators (10000039087)
Primary sources checked .
Compare with
- Westinghouse iGen5000DF Dual Fuel Inverter
120V RV and selected backup loads
- Westinghouse WGen9500DF Dual Fuel Generator
Backup plans requiring verified 240V output
- Champion 201050 4000-Watt Dual Fuel Inverter
Portable 120V loads and compatible RV setups
- DuroMax XP13000EH 13,000-Watt Dual Fuel Portable Generator
Home backup through a 50-amp or 30-amp inlet outside California
- WEN DF475T 4,750-Watt Dual Fuel Portable Generator
240V backup through an L14-30R transfer switch inlet
- DuroMax XP13000HX 13,000-Watt Dual Fuel Generator with CO Alert
Home backup through a 50A inlet with several 120V GFCI outlets