Running Watts product guide
Westinghouse iGen12000DFc Dual Fuel Inverter Generator
Home backup through a 50A or 30A inlet with sensitive electronics
A 457cc dual fuel inverter rated 9,000 running watts on gasoline and 8,100 on propane, with 14-50R and L14-30R outlets, a GFCI duplex, remote and push-button start, and a CO shutoff. It weighs about 189 pounds and needs five feet of clearance. Parallel cables are extra and the maker marks it not CARB compliant.
Listing checked . Confirm the model, included parts and availability before ordering.
Published specifications
- Maker: 12,000 peak / 9,000 run W gasoline; 11,000 / 8,100 W propane
- Outlets: 5-20R GFCI duplex, 14-50R, L14-30R, ST Switch port
- 19 h gas at 25% on 7.9 gal; 9 h propane at 25% on a 20 lb tank
- THD 3% or less; parallel cables sold separately (part 507096)
- Remote, push button and recoil start; battery and charger included
- 3-yr limited: 1 yr parts and labor, yrs 2-3 parts only
Fit and limits
Strengths
- 14-50R and L14-30R outlets with 3% or lower THD
- Remote fob, push-button and recoil starting with automatic choke
- Maker publishes propane runtimes tied to a 20 lb tank
Caveats
- Maker page copy describes the tri fuel model; trust its spec table
- About 189 pounds and five feet of clearance on all sides
- Marked not CARB compliant; labor covered only in year one
A 457cc dual fuel inverter with remote start and a CO sensor
The iGen12000DFc is Westinghouse's 12,000-watt peak, gasoline and propane inverter generator, part number 11023. Amazon's model field, the maker's specification table and the manual cover all name iGen12000DFc, and the UPC on Amazon matches the maker page. It uses a 457cc four-stroke OHV engine, a 7.9-gallon gasoline tank and a THD rating of 3 percent or less.
One caution on the maker's page: its descriptive copy and headline talk about the iGen12000TFc tri fuel model and list natural gas ratings. The specification table on the same page, the Amazon listing and the manual all describe this model as dual fuel, gasoline and propane only. Rely on those, and do not plan to run this unit on natural gas.
Running watts on each fuel and the runtime conditions
Westinghouse rates it at 12,000 peak and 9,000 running watts on gasoline, and 11,000 peak and 8,100 running watts on propane, with the manual and spec table agreeing. If you plan to run on propane, size your loads against 8,100 running watts, not the 12,000 in the listing title. The manual also warns output drops about 3.5 percent for each 1,000 feet of altitude.
Maker runtimes are 19 hours at 25 percent load and 11 hours at 50 percent on gasoline, and 9 hours at 25 percent and 5 hours at 50 percent on a 20-pound propane tank. Amazon's details table shows a 17-hour runtime and a 9.8-gallon tank, which do not match the maker's 19 hours and 7.9 gallons; the manual lists 7.92 gallons.
Outlets: 14-50R, L14-30R, a GFCI duplex and a smart switch port
The spec table lists one 120V 5-20R GFCI duplex, one 120/240V 14-50R, one 120/240V L14-30R and an ST Switch connection, and describes the unit as transfer switch, interlock kit and RV ready. The manual's panel diagram labels the smart switch connector as not included. No TT-30R is listed, so an RV with a 30-amp TT-30 plug needs an adapter that is not in the documents' included lists.
The spec table gives the grounding system as bonded neutral. The manual says not to power a building's electrical system without an approved transfer switch, and the warranty excludes prime power use, meaning use as the main or continuous power source where utility power is unavailable or not used. It is meant for backup, not off-grid living.
Parallel use, Eco Mode and starting
The spec table says it can be paralleled with 240V Westinghouse inverter models using 240V parallel cables sold separately; the manual names compatible cable part 507096 and warns an incompatible generator can cause low voltage. It also says not to use Eco Mode during parallel operation or with inductive loads, and to switch Eco Mode off for large surge loads such as air conditioners or pumps.
Starting is by remote key fob, push button or recoil, with an automatic choke. The manual says the battery ships fully charged and a trickle charger is included to keep it topped up from a wall outlet. After a CO shutdown, a remote-start unit must be restarted from the panel button, not the fob.
Weight, clearance and the CO sensor
The maker lists a dry weight of 189 pounds and Amazon lists 187.4, with dimensions of 30.2 by 25.2 by 26.6 inches. Wheels, axles, mounting stabilizers and the handle are assembled by the owner, and the manual says to get help lifting it and never to lift it by the handle. The noise claim is as low as 64 dBA, with no distance or load stated.
The manual requires at least five feet of clearance on all sides including overhead while running and in storage, a flat level surface, and outdoor use far from occupied buildings with the exhaust pointed away. Its CO sensor shuts the engine off when CO builds up, flashes red after a CO shutoff and yellow for a sensor fault, and does not replace indoor CO alarms. The spec table marks it EPA compliant yes and CARB compliant no.
Oil, break-in and the warranty's labor limit
The unit ships without oil in the crankcase, but a bottle of 10W-30 is included; capacity is 1.1 liters. Check the oil before each use or every 8 hours. For break-in, stay under half the rated running watts for the first five hours and do not use full synthetic oil until the first scheduled change. The manual's schedule adds monthly oil changes under heavy load or high temperatures, and recommends valve adjustment at an approved service center, which is not covered by warranty.
The warranty runs three years for the original purchaser with proof of purchase: parts and labor for one year and replacement parts only for years two and three under consumer use. The maker page lists one year for commercial use. The owner pays shipping to and from a service provider, the starting battery is excluded, and using third-party parts or unaffiliated repair shops does not void it.
Check the current listing
Confirm the model, included parts and availability before ordering.
Primary sources
- Westinghouse product page and specifications for the iGen12000DFc
- Westinghouse iGen12000DFc user manual
- Westinghouse three-year limited warranty for portable generators and inverters
Primary sources checked .
Compare with
- Westinghouse iGen5000DF Dual Fuel Inverter
120V RV and selected backup loads
- Westinghouse WGen9500DF Dual Fuel Generator
Backup plans requiring verified 240V output
- Champion 201050 4000-Watt Dual Fuel Inverter
Portable 120V loads and compatible RV setups
- DuroMax XP13000EH 13,000-Watt Dual Fuel Portable Generator
Home backup through a 50-amp or 30-amp inlet outside California
- WEN DF475T 4,750-Watt Dual Fuel Portable Generator
240V backup through an L14-30R transfer switch inlet
- DuroMax XP13000HX 13,000-Watt Dual Fuel Generator with CO Alert
Home backup through a 50A inlet with several 120V GFCI outlets
Side-by-side pages, this model next to: Westinghouse iGen4000DFcv 4000-Watt Dual Fuel Inverter Generator, DuroStar DS13000MX 13,000-Watt Dual Fuel Portable Generator.